Page #101 background imageLoading...
Page #101 background image
CONFIGURATION
101
Normal Function Settings
Output ON Delay
Time
Delays turning the output on for a designated
amount of time. The Delay indicator will light
when the Delay time is not 0.
Note
The Output ON Delay Time setting has a maximum
deviation (error) of 20ms.
The Output ON Delay Time setting is disabled
when the output is set to external control.
VOLTAGE CURRENT
VSR LAN RMT ERR DLY ALM ISR M 1 M 2 M 3 RUN
C V C C
V A
F-01
0.00s~99.99s
Output OFF
Delay Time
Delays turning the output off for a designated
amount of time. The Delay indicator will light
when the Delay time is not 0.
Note
The Output OFF Delay Time setting has a maximum
deviation (error) of 20ms.
The Output OFF Delay Time setting is disabled
when the output is set to external control.
VOLTAGE CURRENT
VSR LAN RMT ERR DLY ALM ISR M 1 M 2 M 3 RUN
C V C C
V A
F-02
0.00s~99.99s