Home
GW Instek
Power Supply
PSU 100-15
GW Instek PSU 100-15 User Manual
5
of 1
of 1 rating
211 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
OPERA
T
ION
71
PSU
30
-
50
30V
30V
30V
30V
50A
100
A
150A
200A
PSU 40-
38
40V
40V
40V
40V
38A
76A
114A
152A
PSU
50
-
30
50V
50V
50V
50V
30A
60A
90A
120A
PSU 60-
25
60V
60V
60V
60V
25A
50A
75
A
100A
PSU 80-
19
80V
80V
80V
80V
19A
38A
57A
76A
PSU 100
-
15
100V
100V
100V
100V
15A
30A
45A
60A
PSU 150
-
10
150V
150V
150V
150V
10A
20A
30A
40A
PSU 300
-5
300V
300V
300V
300V
5A
10A
15A
20A
PSU 400
-3.8
400V
400V
400V
400V
3.8A
7.6A
11.4A
15.2A
PSU 600
-2.6
600V
600V
600V
600V
2.6A
5.2A
7.8A
10.4A
Master-Slave Parallel Connection
Analog Control
C
onnection
To operate the power
supplies in para
llel with t
he
analog connectors, co
nnect the ana
log connectors
on the master and slave un
its as shown in t
he
diagrams below.
Alternatively, prec
onfigured
cables can be used:
PSU-01C:
1 master with 1 slave
PSU-02C:
1 master with 2 slaves
PSU-03C:
1 master with 3 slaves
70
72
Table of Contents
Table of Contents
3
Safety Instructions
5
Etting Started
9
Getting Started
9
PSU Series Overview
10
Series Lineup
10
Main Features
11
Accessories
12
Appearance
15
PSU Series Front Panel
15
PSU Series Display and Operation Panel
18
Rear Panel
20
Operating Area Description
23
Theory of Operation
23
CC and CV Mode
24
Bleeder Control
26
Slew Rate
26
Internal Resistance
27
Alarms
28
Considerations
29
Grounding
31
Peration
34
Operation
35
Line Voltage Connection
36
Set up
36
Power up
38
Wire Gauge Considerations
39
Output Terminals
40
Using the Output Terminal Cover
42
How to Use the Instrument
43
Using the Rack Mount Kit
43
Reset to Factory Default Settings
45
View System Version and Build Date
46
Basic Operation
49
Setting OVP/OCP/UVL Levels
49
Set to C.V. Priority Mode
52
Set to C.C. Priority Mode
56
Panel Lock
59
Save Setup
59
Recall Setup
60
Remote Sense Connector
61
Voltage Sense
61
Remote Sense Cover
62
Local Sense
63
Remote Sense
63
Parallel / Series Operation
67
Master-Slave Parallel Overview
68
Master-Slave Parallel Connection
71
Master-Slave Parallel Operation
75
Master-Slave Parallel Calibration
77
Master-Slave Series Overview
79
Series Connection
81
Series Operation
82
Test Scripts
85
Test Script File Format
86
Test Script Settings
86
Setting the Test Script Settings
87
Load Test Script from USB
88
Run Test Script
89
Export Test Script to USB
90
Remove Test Script
91
Onfiguration
93
Configuration
93
Configuration Overview
94
Configuration Table
94
Normal Function Settings
101
Interface Configuration Settings
104
USB / GPIB Settings
104
LAN Settings
105
UART Settings
107
System Settings
108
Power on Configuration Settings
109
Trigger Input and Output Configuration Settings
111
Setting Normal Function Settings
112
Special Function
112
Setting Power on Configuration Settings
114
Nalog Control
116
Analog Control
116
Analog Remote Control Overview
117
External Voltage Control of Voltage Output
121
External Voltage Control of Current Output
123
External Resistance Control of Voltage Output
125
External Resistance Control of Current Output
128
External Control of Output
130
External Control of Shutdown
133
External Voltage and Current Monitoring
135
Remote Monitoring
135
External Operation and Status Monitoring
137
External Trigger In/Out
140
Isolated Analog Control Option
142
0~10V Option (PSU-ISO-V)
143
20Ma Option (PSU-ISO-I)
143
Isolated Analog Control Option Specifications
143
Isolated Analog Control Option Overview
144
Isolated External Voltage Control of Voltage Output
145
Isolated External Voltage Control of Current Output
147
Isolated External Current Control of Voltage Output
150
Isolated External Current Control of Current Output
152
Isolated External Voltage and Current Monitoring
154
Ommunication
157
Communication Interface
157
Configuration
158
Interface Configuration
158
USB Remote Interface
158
Function Check
159
Configuration
160
GPIB Remote Interface
160
GPIB Function Check
161
Configure UART
165
UART Remote Interface
165
UART Function Check
169
Legacy Multi-Drop Mode
170
Multiple Unit Connection
170
Multi-Drop Mode
174
Multiple Units Function Check
178
Configure Ethernet Connection
183
Web Server Configuration
183
Web Server Remote Control Function Check
184
Sockets Server Configuration
185
Socket Server Function Check
186
Faq
192
Ppendix
193
Appendix
193
PSU Factory Default Settings
194
Error Messages & Messages
197
LED ASCII Table Character Set
198
Constant Voltage Mode
199
Output
199
PSU Specifications
199
Constant Current Mode
200
Protection Function
201
Analog Programming and Monitoring
202
Front Panel
202
Programming and Measurement
203
Input Characteristics
204
Environment Conditions
205
General Specifications
205
Interface Capabilities
205
Psu 20-76, Psu 30-50, Psu 40-38, Psu
207
Psu 6-200, Psu 8-180, Psu 12.5-120, Psu
207
Psu 60-25
207
PSU Dimensions
207
Psu 400-3.8, Psu 600-2.6
208
Psu 80-19, Psu 100-15, Psu 150-10, Psu
208
Certificate of Compliance
209
Other manuals for GW Instek PSU 100-15
Programming Manual
168 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the GW Instek PSU 100-15 and is the answer not in the manual?
Ask a question
GW Instek PSU 100-15 Specifications
General
Brand
GW Instek
Model
PSU 100-15
Category
Power Supply
Language
English
Related product manuals
GW Instek PSU 150-10
211 pages
GW Instek PSU 12.5-120
211 pages
GW Instek PSU 300-5
211 pages
GW Instek PSU 20-76
211 pages
GW Instek PSU 40-38
211 pages
GW Instek PSU 60-25
211 pages
GW Instek PSU 6-200
196 pages
GW Instek PSU Series
211 pages
GW Instek PSW 80-27
187 pages
GW Instek PSW 30-72
187 pages
GW Instek G PS-3030D
20 pages
GW Instek PSW 30-108
187 pages