PSU Series User Manual
70
Parallel Calibration
The parallel calibration function can be used to
offset cables losses.
External Voltage and Resistance Control
Voltage/Resistance controlled remote control
can only be used with the master unit.
The full scale current (in parallel) is equivalent
to the maximum external voltage or resistance.
Internal Resistance
For 2 units in parallel, the internal resistance is
actually half of the setting value.
For 3 units in parallel, the internal resistance is
actually a third of the setting value.
For 4 units in parallel, the internal resistance is
actually a fourth of the setting value.
See function setting F-08 for internal resistance
settings, page 103.
Bleeder Control
The Master unit is used to control the bleeder
settings. The bleeder resistors in all the slave
units are always turned off when in parallel
mode.
Output Voltage/
Output Current
Model
1 unit
2 units
3 units
4 units
PSU 6-200
6V
6V
6V
6V
200A
400A
600A
800A
PSU 8-180
8V
8V
8V
8V
180A
360A
540A
720A
PSU 12.5-120
12.5V
12.5V
12.5V
12.5V
120A
240A
360A
480A
PSU 15-100
15V
15V
15V
15V
100A
200A
300A
400A
PSU 20-76
20V
20V
20V
20V
76A
152A
228A
304A