EasyManuals Logo

GW Instek PSU 100-15 User Manual

GW Instek PSU 100-15
211 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #203 background imageLoading...
Page #203 background image
APPENDIX
203
Model
PSU
30-50
40-38
50-30
60-25
80-19
Display, 4 digits
Voltage accuracy
0.1% +
mV
60
80
100
120
160
Current accuracy
0.2% +
mA
150
114
90
75
57
Model
PSU
100-15
150-10
300-5
400-3.8
600-2.6
Display, 4 digits
Voltage accuracy
0.1% +
mV
200
300
600
800
1200
Current accuracy
0.2% +
mA
45
30
15
11.4
7.8
Model
PSU All models
Indications
GREEN LED's: CV, CC, V, A, VSR, ISR, DLY, RMT, LAN, M1, M2, M3,
RUN, Output ON
RED LED's: ALM, ERR
Buttons
Lock/Local(Unlock), PROT(ALM_CLR), Function(M1), Test(M2),
Set(M3), Shift, Output
Knobs
Voltage, Current
USB port
Type A USB connector
Programming and Measurement (RS-232/485, USB, LAN,
GPIB)
Model
PSU
6-200
8-180
12.5-120
15-100
20-76
Output voltage
programming accuracy
0.05% +
mV
3
4
6.25
7.5
10
Output current
programming accuracy
0.2% +
mA
200
180
120
100
76
Output voltage
programming resolution
mV
0.2
0.27
0.4
0.5
0.7
Output current
programming resolution
mA
6
6
4
3.3
2.5
Output voltage
measurement accuracy
0.1% +
mV
6
8
12.5
15
20
Output current
measurement accuracy
0.2% +
mA
400
360
240
200
152
Output voltage
measurement resolution
mV
0.2
0.27
0.4
0.5
0.7
Output current
measurement resolution
mA
6
6
4
3.3
2.5
Model
PSU
30-50
40-38
50-30
60-25
80-19
Output voltage
programming accuracy
0.05% +
mV
15
20
25
30
40
Output current
programming accuracy
0.2% +
mA
50
38
30
25
19
Output voltage
programming resolution
mV
1
1.3
1.7
2
2.7

Table of Contents

Other manuals for GW Instek PSU 100-15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU 100-15 and is the answer not in the manual?

GW Instek PSU 100-15 Specifications

General IconGeneral
BrandGW Instek
ModelPSU 100-15
CategoryPower Supply
LanguageEnglish

Related product manuals