PSU Series User Manual
74
Example with
negative terminal
connected to
ground
Slave #1
Master
Load
Input
Input
Output
Ground
Output
Output
Ground
Output
Slave #2
Output
Ground
Output
Steps
1. Ensure the power is off on all power supplies.
2. Choose a master and a slave unit(s).
3. Connect the analog connectors for the master
and slave units as shown above.
4. Remove the Output Terminal
covers.
Page 42
5. Connect the master and slave unit in parallel as
shown above.
6. Reattach the terminal covers.
Page 42
Ensure the load cables have sufficient
current capacity.
Page 39
The load wires and remote sense wires should use
twisted-paired wiring of the shortest possible length.