REMOTE CONTROL 
25 
USB Remote Control Function Check 
 
Functionality 
check  
Invoke a terminal application such as Hyper 
Terminal. 
To check the COM port No, see the Device 
Manager in the PC. For WinXP; Control panel 
→ System → Hardware tab. 
 
Run this query command via the terminal after 
the instrument has been configured for USB 
remote control (page 22). 
*idn? 
This should return the Manufacturer, Model 
number, Serial number, and Firmware version 
in the following format. 
GW-INSTEK,PSW-3036,TW123456,01.00.20110101 
Manufacturer: GW-INSTEK 
Model number : PSW-3036 
Serial number : TW123456 
Firmware version : 01.00.20110101 
  ^j can be used as the terminal character when 
entering the queries/commands from a terminal 
application. 
Web Server Remote Control Function Check 
 
Functionality 
check   
Enter the IP address of the power supply in a 
web browser after the instrument has been 
configured as a web server (page 24). 
http:// XXX.XXX.XXX.XXX 
The web browser interface appears.