32 HVAD® Instructions for Use
10
9
8
7
6
5
4
3
2
1
Appendix
Reference
Guides
Alarms and
Emergencies
Patient
Management
Surgical
Implant and
Explant
Monitor
Peripherals
and
Accessories
HVAD
®
Pump Overview
Introduction
1.8 US Clinical Study: Destination Therapy (continued)
Figure 10:
Adverse events

presented in Table 16 below. Patients in the HVAD arm had a higher rate of ischemic and
hemorrhagic stroke, sepsis, and right heart failure compared to control. An analysis of the
patient-level data indicated that elevated blood pressure appeared to be a risk factor for
stroke, particularly hemorrhagic stroke.