C. No Spark At Spark Plug
Check Ignition Switch
Check Spark Plug for
Fouling/Improper
Electrode Gap
OK
OK
OK
Check for Poorly Connected
or Loose Spark Plug Wire
LooseContact
No Spark
“OFF” ( ) Position
Secure Properly
Replace Spark Plug/Adjust
Spark Plug Gap (0.6-0.7 mm)
Turn Ignition Switch “ON” ( )
2. ENGINE STARTS BUT STALLS
“OFF” Position
Check Air Cleaner Element
OK
Dirty/Clogged
“ON”
Turn it “OFF” Position
Clean and Refit
Check Choke Knob
Position
Consult Authorised Hero MotoCorp Workshop