Figure 3-6 Input Signal Connecting to NPN Device without Pull-Up Resistor
If the VCC of NPN device is 12 VDC or 24 VDC and 1 KΩ pull-up resistor is used, its wiring is as
follows.
Figure 3-7 Input Signal Connecting to NPN Device with Pull-Up Resistor
3.4 Output Signal Wiring
The device can output signal to external device via I/O interface, and here we take LineOut 0 and
type I device as an example to introduce output signal wiring.
Note
●
Output signal wiring may differ with different types of external devices.
●
The voltage of VCC should not higher than that of PWR. Otherwise, the device's output signal
may have exception.