ID5000 Series Smart Code Reader User Manual
9
Device Power
PWR
Device Power Ground
NPN
Device
NPN Device Power
VCC
GND of PWR
Input Signal
Ground
GND of VCC
Opto-Isolated Input
Signal Line
NPN Power Ground
Figure 3-6 Input Signal Connecting to NPN Device without Pull-Up Resistor
If the VCC of NPN device is 12 VDC or 24 VDC and 1 KΩ pull-up resistor is used, its wiring is as
follows.
Opto-Isolated
Input
Device Power
PWR
Device Power Ground
NPN
Device
NPN Device Power
NPN Power Ground
Signal Line
VCC
GND of PWR
Input Signal Ground
GND of VCC
Figure 3-7 Input Signal Connecting to NPN Device with Pull-Up Resistor
3.4 Output Signal Wiring
The device can output signal to external device via I/O interface, and here we take LineOut 0 and
type I device as an example to introduce output signal wiring.
Note
Output signal wiring may differ with different types of external devices.
The voltage of VCC should not higher than that of PWR. Otherwise, the device's output signal
may have exception.