ID5000 Series Smart Code Reader User Manual
55
Figure 8-38 Select Output Signal
8.4.2 Enable Line Inverter
The level inverter function allows the device to invert the electrical signal level of an I/O line, and
meets requirements of different devices for high or low electrical signal level.
You can go to I/O Control Settings Output Line Out Inverter to enable it.
Note
The Line Out Inverter function is disabled by default.
Figure 8-39 Enable Line Out Inverter
8.4.3 Set Event Source
The device supports outputting different trigger signals according to the event source you select.
Click I/O Control Settings Output Line Out Activation Event to select event source.
The device supports following event sources, including Acquisition Start Active, Acquisition Stop
Active, Frame Burst Start Active, Frame Burst Stop Active, Exposure Start Active, Soft Trigger
Active, Hard Trigger Active, Counter Active, Timer Active, No Code Read, Read Success, and Light
Strobe Long, Compare Success, and Compare Fail.
Note
Off refers to no event source.
Some event sources support the function of trigger output cache, and you can go to Feature
Tree Trigger and IO Control > Line Out Cache to enable it.