ID5000 Series Smart Code Reader User Manual
21
Chapter 7 Device Mode Settings
The device supports 3 types of operating modes, including Test, Normal, and Raw. You can select
different modes in live view window according to actual demands.
Note
Stopping the real-time acquisition is required before selecting modes.
You need to set device mode as Normal before specific device settings. Otherwise, the device
parameters may be different.
Figure 7-1 Select Device Mode
Table 7-1 Device Mode Description
Device Mode
Description
Test Mode
It is used during device debugging. The device outputs images that are
acquired in real-time, and displays code information.
Normal Mode
It is used during device normal operation. After reading code in image, the
device outputs image and code information.
Raw Mode
It is used during testing image data. The device outputs raw data and displays
code information.
You can click in the live view window to view images and the code reading effect. If the effect is
not very good, you can adjust related parameters like exposure time, gain, Gamma, etc. in Image
Settings area.