ID5000 Series Smart Code Reader User Manual
44
Steps
1. Set Sym Proc Type according to actual demands, and the default type is Type 1. Type 1 has a
strong capacity to locate codes.
2. Set Iso Edition, including Iso15415 and Iso29158
●
Iso15415 is applicable to the quality evaluation for label 2-dimensional codes.
●
Iso29158 is applicable to the quality evaluation for DPM format 2-dimensional codes.
3. Set Verify Edition, including standard mode and HIK mode.
●
Standard mode is a standard quality evaluation mode.
●
HIK mode is a professional quality evaluation mode.
4. Set Standard Aperture and Magnification.
●
Standard aperture refers to a standard aperture, and its default value is 400.
●
Magnification is 150 by default.
Note
Standard Aperture and Magnification should be configured only when Type 2 is selected as Sym
Proc Type.
5. Click to start acquisition, and the client software will display the overall code quality in the
history area.
Figure 8-21 2D Code Quality Evaluation
Note
The overall grade includes A, B, C, D and F. A means that the code quality is the best while F means
that the code quality is the worst.
6. (Optional) Click specific grade in the overall grade list to view different quantity evaluation
items.
8.2.6 Set Code Score
After enabling code score function, the client software can output specific score for codes it has
read.
Note
●
The function of code score may differ by device models.
●
In test mode, this function is enabled by default. In normal mode, you need to enable it manually.