ID5000 Series Smart Code Reader User Manual
46
mode.
Internal Trigger Mode
In this mode, the device acquires images via its internal signals.
External Trigger Mode
In this mode, the device acquires images via external signals like software signal and hardware
signal. The trigger source of external trigger mode includes software, physical lines, counter,
TCP, UDP, serial port and self trigger.
Note
The specific external trigger mode may differ by device models.
8.3.2 Enable Internal Trigger Mode
In the internal trigger mode, the device acquires images via its internal signals. You have 2
methods to enable the internal trigger mode:
Click I/O Control Settings Input Trigger Mode, and select Off as Trigger Mode.
In the live view page, click to enable the internal trigger mode.
8.3.3 Enable External Trigger Mode
In the external trigger mode, the device acquires images via external signals like software signal
and hardware signal. You have 2 methods to enable the external trigger mode:
Click I/O Control Settings Input Trigger Mode, and select On as Trigger Mode.
In the live view page, click to enable the external trigger mode.
Set and Execute Software Trigger Mode
In software trigger, the software sends trigger signal to the device via I/O interface to acquire
images.
Steps
1. Click I/O Control Settings Input Trigger Mode.
2. Select On as Trigger Mode.
3. Select Software as Trigger Source.
4. Click Execute in Trigger Source to send trigger commands.
You can also enter Auto Trigger Time, and then enable Enable Auto Trigger to let the client
software automatically send trigger signal to device according to the interval you set.