ID5000 Series Smart Code Reader User Manual
56
Acquisition Start Active
If acquisition starts, the output signal will be triggered.
Acquisition Stop Active
If acquisition stops, the output signal will be triggered.
Frame Burst Start Active
If the burst of a frame starts, the output signal will be triggered.
Frame Burst Stop Active
If the burst of a frame stops, the output signal will be triggered.
Exposure Start Active
If the exposure starts, the output signal will be triggered.
Soft Trigger Active
The client software triggers the output signal.
Hard Trigger Active
The external signals trigger the output signal.
Counter Active
Trigger the output signal by the counter.
Timer Active
The timer triggers the output signal.
No Code Read
If no code read by the device, the output signal will be triggered.
Read Success
If the code is read by the device, the output signal will be triggered.
Light Strobe Long
If the light mode is Strobe Long, the output signal will be triggered.
Compare Success
If data comparison is successful, the output signal will be triggered.
Compare Fail
If data comparison is failed, the output signal will be triggered.
Note
You need to set different parameters when selecting these event sources.