Table 7-3 Temperature Measurement Parameters Descripons
Parameter Descripon
Temp. Detecon When enabling the funcon, the device will authencate the
permissions and at the same me take the temperature. When
disabling the device, the device will authencate the
permissions only.
Norm Temp. (Max./Min.) Edit the threshold according to actual situaon. If the detected
temperature is higher or lower than the congured parameters,
an alarm will be triggered. By default, the value is 37.3°.
Temp. Compensaon If the measured temperature is higher/lower than the actual
object's temperature, you can set the compensaon
temperature here. Available range: -99 °C to 99 °C
Door Not Open (Abnormal
Temp.)
When enabling the funcon, the door will not open when the
detected temperature is higher or lower than the congured
temperature threshold. By default, the funcon is enabled.
Temperature Measurement
Only
When enabling the funcon, the device will not authencate the
permissions, but only take the temperature. When disabling the
funcon, the device will authencate the permissions and at the
same
me take the temperature.
Unit Select a temperature unit according to your preference.
Measurement Area Calibraon Congure the temperature measurement area.
DS-K1TA70 Series Face Recognion Terminal User Manual
67

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-K1TA70 Series and is the answer not in the manual?

HIKVISION DS-K1TA70 Series Specifications

General IconGeneral
BrandHIKVISION
ModelDS-K1TA70 Series
CategoryTouch terminals
LanguageEnglish

Related product manuals