Chapter 3 Installaon
3.1 Installaon Environment
Avoid backlight, direct sunlight, and indirect sunlight.
For
beer face recognion, there should be light source in or near the installaon environment.
Sunlight, wind, hot/cool air from air
condioner and other external factors, which may aect
temperature, will create the deviaon of the temperature measurement. In order to get an
accurate result, make sure the device is applied indoors and windlessly (where is relavely
isolated from the outdoors). The working temperature should keep between 10 °C and 35 °C. If
there are no suitable environments for temperature measurement (the area faces the indoor
and connects the outdoor, the area at the door of the indoor environment, etc.), building a
temporary temperature measurement environment is suggested.
Inuence Factors of Temperature Measurement:
Wind: The wind will take the heat away, which may
aect the measurement result.
Sweat: The sweat will take the heat away, which may aect the measurement result.
Air Condioner (Cool Air): If the indoor temperature is low, the temperature may also lower than
the actual temperature, which may
aect the measurement result.
Air Condioner (Heat) or Heang: If the indoor temperature is high, the temperature may also
higher than the actual temperature, which may
aect the measurement result.
In order to make the device work properly, you should wait for 90 min aer the device is
powered on.
For details about
installaon environment, see Tips for Installaon Environment .
3.2 Flush
Mounng
Steps
1.
Install a gang box.
2.
Connect the thermographic module and the main body.