qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
110E
broken wire
Sensor Error: IOPiston4
Faulty pressure or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
120E
circuit ground
130E
circuit battery
140E
module error
150E
output deactivated
160E
error +UB
170E
data error / CAN error
180E
timeout / CAN timeout
190E
safety error
1A0E
parameter error
1B0E
unspecified error
1C0E
missing adjustment
110F
broken wire
Sensor Error: IORod4
Faulty pressure or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
120F
circuit ground
130F
circuit battery
140F
module error
150F
output deactivated
160F
error +UB
170F
data error / CAN error
180F
timeout / CAN timeout
190F
safety error
1A0F
parameter error
1B0F
unspecified error
1C0F
missing adjustment
1110
broken wire
Sensor Error: IOPin-
ning1
Locking pin initialization
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1210
circuit ground
1310
circuit battery
1410
module error
1510
output deactivated
1610
error +UB
1710
data error / CAN error
1810
timeout / CAN timeout
1910
safety error
1A10
parameter error
1B10
unspecified error
1C10
missing adjustment