EasyManua.ls Logo

Hirschmann qSCALE i2 - Page 99

Hirschmann qSCALE i2
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 99/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
110B
broken wire
Sensor Error: IORod3
Faulty pressure or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
120B
circuit ground
130B
circuit battery
140B
module error
150B
output deactivated
160B
error +UB
170B
data error / CAN error
180B
timeout / CAN timeout
190B
safety error
1A0B
parameter error
1B0B
unspecified error
1C0B
missing adjustment
110C
broken wire
Sensor Error:
IOLength4
Length sensor failure or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
120C
circuit ground
130C
circuit battery
140C
module error
150C
output deactivated
160C
error +UB
170C
data error / CAN error
180C
timeout / CAN timeout
190C
safety error
1A0C
parameter error
1B0C
unspecified error
1C0C
missing adjustment
110D
broken wire
Sensor Error: IOAngle4
Angle fault or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
120D
circuit ground
130D
circuit battery
140D
module error
150D
output deactivated
160D
error +UB
170D
data error / CAN error
180D
timeout / CAN timeout
190D
safety error
1A0D
parameter error
1B0D
unspecified error
1C0D
missing adjustment

Other manuals for Hirschmann qSCALE i2