Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 98/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1108
broken wire
Sensor Error:
IOLength3
Length sensor failure or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1208
circuit ground
1308
circuit battery
1408
module error
1508
output deactivated
1608
error +UB
1708
data error / CAN error
1808
timeout / CAN timeout
1908
safety error
1A08
parameter error
1B08
unspecified error
1C08
missing adjustment
1109
broken wire
Sensor Error: IOAngle3
Angle fault or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1209
circuit ground
1309
circuit battery
1409
module error
1509
output deactivated
1609
error +UB
1709
data error / CAN error
1809
timeout / CAN timeout
1909
safety error
1A09
parameter error
1B09
unspecified error
1C09
missing adjustment
110A
broken wire
Sensor Error: IOPiston3
Faulty pressure or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
120A
circuit ground
130A
circuit battery
140A
module error
150A
output deactivated
160A
error +UB
170A
data error / CAN error
180A
timeout / CAN timeout
190A
safety error
1A0A
parameter error
1B0A
unspecified error
1C0A
missing adjustment