Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 106/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1120
broken wire
Sensor Error: IOForce1
Force measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1220
circuit ground
1320
circuit battery
1420
module error
1520
output deactivated
1620
error +UB
1720
data error / CAN error
1820
timeout / CAN timeout
1920
safety error
1A20
parameter error
1B20
unspecified error
1C20
missing adjustment
1121
broken wire
Sensor Error: IOForce2
Force measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1221
circuit ground
1321
circuit battery
1421
module error
1521
output deactivated
1621
error +UB
1721
data error / CAN error
1821
timeout / CAN timeout
1921
safety error
1A21
parameter error
1B21
unspecified error
1C21
missing adjustment
1122
broken wire
Sensor Error: IOForce3
Force measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1222
circuit ground
1322
circuit battery
1422
module error
1522
output deactivated
1622
error +UB
1722
data error / CAN error
1822
timeout / CAN timeout
1922
safety error
1A22
parameter error
1B22
unspecified error
1C22
missing adjustment