© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 107/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1123
broken wire
Sensor Error: IOForce4
Force measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1223
circuit ground
1323
circuit battery
1423
module error
1523
output deactivated
1623
error +UB
1723
data error / CAN error
1823
timeout / CAN timeout
1923
safety error
1A23
parameter error
1B23
unspecified error
1C23
missing adjustment
1124
broken wire
Sensor Error: IOForce5
Force measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1224
circuit ground
1324
circuit battery
1424
module error
1524
output deactivated
1624
error +UB
1724
data error / CAN error
1824
timeout / CAN timeout
1924
safety error
1A24
parameter error
1B24
unspecified error
1C24
missing adjustment
1125
broken wire
Sensor Error: IOForce6
Force measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1225
circuit ground
1325
circuit battery
1425
module error
1525
output deactivated
1625
error +UB
1725
data error / CAN error
1825
timeout / CAN timeout
1925
safety error
1A25
parameter error
1B25
unspecified error
1C25
missing adjustment

Other manuals for Hirschmann qSCALE i2