Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 108/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1126
broken wire
Sensor Error: IOForce7
Force measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1226
circuit ground
1326
circuit battery
1426
module error
1526
output deactivated
1626
error +UB
1726
data error / CAN error
1826
timeout / CAN timeout
1926
safety error
1A26
parameter error
1B26
unspecified error
1C26
missing adjustment
1127
broken wire
Sensor Error: IOForce8
Force measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1227
circuit ground
1327
circuit battery
1427
module error
1527
output deactivated
1627
error +UB
1727
data error / CAN error
1827
timeout / CAN timeout
1927
safety error
1A27
parameter error
1B27
unspecified error
1C27
missing adjustment
1128
broken wire
Sensor Error: IOSlew1
Faulty slew or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1228
circuit ground
1328
circuit battery
1428
module error
1528
output deactivated
1628
error +UB
1728
data error / CAN error
1828
timeout / CAN timeout
1928
safety error
1A28
parameter error
1B28
unspecified error
1C28
missing adjustment