EasyManua.ls Logo

Hirschmann qSCALE i2 - Page 109

Hirschmann qSCALE i2
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 109/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1129
broken wire
Sensor Error: IOSlew2
Faulty slew or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1229
circuit ground
1329
circuit battery
1429
module error
1529
output deactivated
1629
error +UB
1729
data error / CAN error
1829
timeout / CAN timeout
1929
safety error
1A29
parameter error
1B29
unspecified error
1C29
missing adjustment
112A
broken wire
Sensor Error: IOSlew3
Faulty slew or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
122A
circuit ground
132A
circuit battery
142A
module error
152A
output deactivated
162A
error +UB
172A
data error / CAN error
182A
timeout / CAN timeout
192A
safety error
1A2A
parameter error
1B2A
unspecified error
1C2A
missing adjustment
112B
broken wire
Sensor Error: IOSlew4
Faulty slew or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
122B
circuit ground
132B
circuit battery
142B
module error
152B
output deactivated
162B
error +UB
172B
data error / CAN error
182B
timeout / CAN timeout
192B
safety error
1A2B
parameter error
1B2B
unspecified error
1C2B
missing adjustment

Other manuals for Hirschmann qSCALE i2