EasyManua.ls Logo

Hirschmann qSCALE i2 - Page 110

Hirschmann qSCALE i2
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 110/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
112C
broken wire
Sensor Error: IOMAn-
gle1
Faulty angle measure-
ment or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
122C
circuit ground
132C
circuit battery
142C
module error
152C
output deactivated
162C
error +UB
172C
data error / CAN error
182C
timeout / CAN timeout
192C
safety error
1A2C
parameter error
1B2C
unspecified error
1C2C
missing adjustment
112D
broken wire
Sensor Error: IOMAn-
gle2
Faulty angle measure-
ment or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
122D
circuit ground
132D
circuit battery
142D
module error
152D
output deactivated
162D
error +UB
172D
data error / CAN error
182D
timeout / CAN timeout
192D
safety error
1A2D
parameter error
1B2D
unspecified error
1C2D
missing adjustment
112E
broken wire
Sensor Error: IOMAn-
gle3
Faulty angle measure-
ment or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
122E
circuit ground
132E
circuit battery
142E
module error
152E
output deactivated
162E
error +UB
172E
data error / CAN error
182E
timeout / CAN timeout
192E
safety error
1A2E
parameter error
1B2E
unspecified error
1C2E
missing adjustment