qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1132
broken wire
Sensor Error: IOOutrig-
ger3
Outrigger initialization
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1232
circuit ground
1332
circuit battery
1432
module error
1532
output deactivated
1632
error +UB
1732
data error / CAN error
1832
timeout / CAN timeout
1932
safety error
1A32
parameter error
1B32
unspecified error
1C32
missing adjustment
1133
broken wire
Sensor Error: IOOutrig-
ger4
Outrigger initialization
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1233
circuit ground
1333
circuit battery
1433
module error
1533
output deactivated
1633
error +UB
1733
data error / CAN error
1833
timeout / CAN timeout
1933
safety error
1A33
parameter error
1B33
unspecified error
1C33
missing adjustment
1134
broken wire
Sensor Error: IOWind1
Wind Speed fault or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1234
circuit ground
1334
circuit battery
1434
module error
1534
output deactivated
1634
error +UB
1734
data error / CAN error
1834
timeout / CAN timeout
1934
safety error
1A34
parameter error
1B34
unspecified error
1C34
missing adjustment