Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 114/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1138
broken wire
Sensor Error: IOIncX1
Inclination measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1238
circuit ground
1338
circuit battery
1438
module error
1538
output deactivated
1638
error +UB
1738
data error / CAN error
1838
timeout / CAN timeout
1938
safety error
1A38
parameter error
1B38
unspecified error
1C38
missing adjustment
1139
broken wire
Sensor Error: IOIncY1
Inclination measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1239
circuit ground
1339
circuit battery
1439
module error
1539
output deactivated
1639
error +UB
1739
data error / CAN error
1839
timeout / CAN timeout
1939
safety error
1A39
parameter error
1B39
unspecified error
1C39
missing adjustment
113A
broken wire
Sensor Error: IOIncX2
Inclination measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
123A
circuit ground
133A
circuit battery
143A
module error
153A
output deactivated
163A
error +UB
173A
data error / CAN error
183A
timeout / CAN timeout
193A
safety error
1A3A
parameter error
1B3A
unspecified error
1C3A
missing adjustment