Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 115/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
113B
broken wire
Sensor Error: IOIncY2
Inclination measurement
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
123B
circuit ground
133B
circuit battery
143B
module error
153B
output deactivated
163B
error +UB
173B
data error / CAN error
183B
timeout / CAN timeout
193B
safety error
1A3B
parameter error
1B3B
unspecified error
1C3B
missing adjustment
113C
broken wire
Sensor Error: IO-
MaxA2B1
A2B switch failure or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
123C
circuit ground
133C
circuit battery
143C
module error
153C
output deactivated
163C
error +UB
173C
data error / CAN error
183C
timeout / CAN timeout
193C
safety error
1A3C
parameter error
1B3C
unspecified error
1C3C
missing adjustment
113D
broken wire
Sensor Error: IO-
MaxA2B2
A2B switch failure or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
123D
circuit ground
133D
circuit battery
143D
module error
153D
output deactivated
163D
error +UB
173D
data error / CAN error
183D
timeout / CAN timeout
193D
safety error
1A3D
parameter error
1B3D
unspecified error
1C3D
missing adjustment

Other manuals for Hirschmann qSCALE i2