Error
Code
Description
Cause
Notice/Solution
116E
broken wire
Actuator Error: IOLam-
pRed
Faulty Lamp (red) output
or the output module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
126E
circuit ground
136E
circuit battery
146E
module error
156E
output deactivated
166E
error +UB
176E
data error / CAN error
186E
timeout / CAN timeout
196E
safety error
1A6E
parameter error
1B6E
unspecified error
1C6E
missing adjustment
116F
broken wire
Actuator Error: IOHorn
Faulty Horn output or the
output module is defec-
tive
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
126F
circuit ground
136F
circuit battery
146F
module error
156F
output deactivated
166F
error +UB
176F
data error / CAN error
186F
timeout / CAN timeout
196F
safety error
1A6F
parameter error
1B6F
unspecified error
1C6F
missing adjustment
1170
broken wire
Sensor Error: IOSafe-
ty1C
Faulty Safety Relay
feedback input or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1270
circuit ground
1370
circuit battery
1470
module error
1570
output deactivated
1670
error +UB
1770
data error / CAN error
1870
timeout / CAN timeout
1970
safety error
1A70
parameter error
1B70
unspecified error
1C70
missing adjustment

Other manuals for Hirschmann qSCALE i2