qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
116B
broken wire
Actuator Error: IO-
WinchDown
Faulty Winch Out Enable
output or the output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
126B
circuit ground
136B
circuit battery
146B
module error
156B
output deactivated
166B
error +UB
176B
data error / CAN error
186B
timeout / CAN timeout
196B
safety error
1A6B
parameter error
1B6B
unspecified error
1C6B
missing adjustment
116C
broken wire
Actuator Error:
IOLampGreen
Faulty Lamp (green)
output or the output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
126C
circuit ground
136C
circuit battery
146C
module error
156C
output deactivated
166C
error +UB
176C
data error / CAN error
186C
timeout / CAN timeout
196C
safety error
1A6C
parameter error
1B6C
unspecified error
1C6C
missing adjustment
116D
broken wire
Actuator Error:
IOLampYellow
Faulty Lamp (yellow)
output or the output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
126D
circuit ground
136D
circuit battery
146D
module error
156D
output deactivated
166D
error +UB
176D
data error / CAN error
186D
timeout / CAN timeout
196D
safety error
1A6D
parameter error
1B6D
unspecified error
1C6D
missing adjustment