Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 139/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1183
broken wire
Actuator Error: IOOut-
put6
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1283
circuit ground
1383
circuit battery
1483
module error
1583
output deactivated
1683
error +UB
1783
data error / CAN error
1883
timeout / CAN timeout
1983
safety error
1A83
parameter error
1B83
unspecified error
1C83
missing adjustment
1184
broken wire
Actuator Error: IOOut-
put7
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1284
circuit ground
1384
circuit battery
1484
module error
1584
output deactivated
1684
error +UB
1784
data error / CAN error
1884
timeout / CAN timeout
1984
safety error
1A84
parameter error
1B84
unspecified error
1C84
missing adjustment
1185
broken wire
Actuator Error: IOOut-
put8
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1285
circuit ground
1385
circuit battery
1485
module error
1585
output deactivated
1685
error +UB
1785
data error / CAN error
1885
timeout / CAN timeout
1985
safety error
1A85
parameter error
1B85
unspecified error
1C85
missing adjustment

Other manuals for Hirschmann qSCALE i2