© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 138/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1180
broken wire
Actuator Error: IOOut-
put3
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1280
circuit ground
1380
circuit battery
1480
module error
1580
output deactivated
1680
error +UB
1780
data error / CAN error
1880
timeout / CAN timeout
1980
safety error
1A80
parameter error
1B80
unspecified error
1C80
missing adjustment
1181
broken wire
Actuator Error: IOOut-
put4
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1281
circuit ground
1381
circuit battery
1481
module error
1581
output deactivated
1681
error +UB
1781
data error / CAN error
1881
timeout / CAN timeout
1981
safety error
1A81
parameter error
1B81
unspecified error
1C81
missing adjustment
1182
broken wire
Actuator Error: IOOut-
put5
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1282
circuit ground
1382
circuit battery
1482
module error
1582
output deactivated
1682
error +UB
1782
data error / CAN error
1882
timeout / CAN timeout
1982
safety error
1A82
parameter error
1B82
unspecified error
1C82
missing adjustment