Error
Code
Description
Cause
Notice/Solution
117D
broken wire
Sensor Error: IOTemp2
Faulty Temperature
sensor or input module
is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
127D
circuit ground
137D
circuit battery
147D
module error
157D
output deactivated
167D
error +UB
177D
data error / CAN error
187D
timeout / CAN timeout
197D
safety error
1A7D
parameter error
1B7D
unspecified error
1C7D
missing adjustment
117E
broken wire
Actuator Error: IOOut-
put1
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
127E
circuit ground
137E
circuit battery
147E
module error
157E
output deactivated
167E
error +UB
177E
data error / CAN error
187E
timeout / CAN timeout
197E
safety error
1A7E
parameter error
1B7E
unspecified error
1C7E
missing adjustment
117F
broken wire
Actuator Error: IOOut-
put2
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
127F
circuit ground
137F
circuit battery
147F
module error
157F
output deactivated
167F
error +UB
177F
data error / CAN error
187F
timeout / CAN timeout
197F
safety error
1A7F
parameter error
1B7F
unspecified error
1C7F
missing adjustment