Error
Code
Description
Cause
Notice/Solution
117A
broken wire
Actuator Error: IOUp
Faulty Ascend Output or
input module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
127A
circuit ground
137A
circuit battery
147A
module error
157A
output deactivated
167A
error +UB
177A
data error / CAN error
187A
timeout / CAN timeout
197A
safety error
1A7A
parameter error
1B7A
unspecified error
1C7A
missing adjustment
117B
broken wire
Actuator Error: IODown
Faulty Descend Output
or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
127B
circuit ground
137B
circuit battery
147B
module error
157B
output deactivated
167B
error +UB
177B
data error / CAN error
187B
timeout / CAN timeout
197B
safety error
1A7B
parameter error
1B7B
unspecified error
1C7B
missing adjustment
117C
broken wire
Sensor Error: IOTemp1
Faulty Temperature
sensor or input module
is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
127C
circuit ground
137C
circuit battery
147C
module error
157C
output deactivated
167C
error +UB
177C
data error / CAN error
187C
timeout / CAN timeout
197C
safety error
1A7C
parameter error
1B7C
unspecified error
1C7C
missing adjustment