Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 146/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
11A3
broken wire
Slew Angle
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12A3
circuit ground
13A3
circuit battery
14A3
module error
15A3
output deactivated
16A3
error +UB
17A3
data error / CAN error
18A3
timeout / CAN timeout
19A3
safety error
1AA3
parameter error
1BA3
unspecified error
1CA3
missing adjustment
11A4
broken wire
Boom Angle
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12A4
circuit ground
13A4
circuit battery
14A4
module error
15A4
output deactivated
16A4
error +UB
17A4
data error / CAN error
18A4
timeout / CAN timeout
19A4
safety error
1AA4
parameter error
1BA4
unspecified error
1CA4
missing adjustment
11A5
broken wire
Boom Length
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12A5
circuit ground
13A5
circuit battery
14A5
module error
15A5
output deactivated
16A5
error +UB
17A5
data error / CAN error
18A5
timeout / CAN timeout
19A5
safety error
1AA5
parameter error
1BA5
unspecified error
1CA5
missing adjustment