Error
Code
Description
Cause
Notice/Solution
11A6
broken wire
Superstructure Inclina-
tion X
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12A6
circuit ground
13A6
circuit battery
14A6
module error
15A6
output deactivated
16A6
error +UB
17A6
data error / CAN error
18A6
timeout / CAN timeout
19A6
safety error
1AA6
parameter error
1BA6
unspecified error
1CA6
missing adjustment
11A7
broken wire
Superstructure Inclina-
tion Y
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12A7
circuit ground
13A7
circuit battery
14A7
module error
15A7
output deactivated
16A7
error +UB
17A7
data error / CAN error
18A7
timeout / CAN timeout
19A7
safety error
1AA7
parameter error
1BA7
unspecified error
1CA7
missing adjustment
11A8
broken wire
Environment Tempera-
ture
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12A8
circuit ground
13A8
circuit battery
14A8
module error
15A8
output deactivated
16A8
error +UB
17A8
data error / CAN error
18A8
timeout / CAN timeout
19A8
safety error
1AA8
parameter error
1BA8
unspecified error
1CA8
missing adjustment