Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 150/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
11AF
broken wire
Rod Pressure Cyl. 2
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12AF
circuit ground
13AF
circuit battery
14AF
module error
15AF
output deactivated
16AF
error +UB
17AF
data error / CAN error
18AF
timeout / CAN timeout
19AF
safety error
1AAF
parameter error
1BAF
unspecified error
1CAF
missing adjustment
11B0
broken wire
Load measurement
outrigger front left
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12B0
circuit ground
13B0
circuit battery
14B0
module error
15B0
output deactivated
16B0
error +UB
17B0
data error / CAN error
18B0
timeout / CAN timeout
19B0
safety error
1AB0
parameter error
1BB0
unspecified error
1CB0
missing adjustment
11B1
broken wire
Load measurement
outrigger front center
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12B1
circuit ground
13B1
circuit battery
14B1
module error
15B1
output deactivated
16B1
error +UB
17B1
data error / CAN error
18B1
timeout / CAN timeout
19B1
safety error
1AB1
parameter error
1BB1
unspecified error
1CB1
missing adjustment