© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 149/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
11AC
broken wire
Piston Pressure Cyl. 1
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12AC
circuit ground
13AC
circuit battery
14AC
module error
15AC
output deactivated
16AC
error +UB
17AC
data error / CAN error
18AC
timeout / CAN timeout
19AC
safety error
1AAC
parameter error
1BAC
unspecified error
1CAC
missing adjustment
11AD
broken wire
Rod Pressure Cyl. 1
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12AD
circuit ground
13AD
circuit battery
14AD
module error
15AD
output deactivated
16AD
error +UB
17AD
data error / CAN error
18AD
timeout / CAN timeout
19AD
safety error
1AAD
parameter error
1BAD
unspecified error
1CAD
missing adjustment
11AE
broken wire
Piston Pressure Cyl. 2
Error on value
Check the sensors and actuators. Data
Programming does not cover the operating
state. Consult Customer Service if the error
occurs again
12AE
circuit ground
13AE
circuit battery
14AE
module error
15AE
output deactivated
16AE
error +UB
17AE
data error / CAN error
18AE
timeout / CAN timeout
19AE
safety error
1AAE
parameter error
1BAE
unspecified error
1CAE
missing adjustment