Troubleshooting
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 20/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
3.1.2.1.3 Analog Input Screen
Analog Input Screen shows all of the configured analog inputs for the system, including CAN sensors.
These outputs are wired from the DIO Box; refer to your crane system wiring diagram for details. Use
the rotary knob to scroll between all available outputs.
MAIN
WORKING
SCREEN
OP-MODE
CONFIRM
INFORMATION
SELECTION
SENSOR
INFORMATION
ANALOG
INPUTS
Delete Sensor Calibration
Set Zero Point Offset
Set Current Sensor Raw Value as
Raw-Value Scale Start
Inverts Raw Value
(100% minus raw value)
Set Current Sensor Raw Value as
Raw-Value Scale End
Additional Information
(see Section 3.1.2.1.4)
The following information can be found on this screen:
Value Current Value
Fault Indication whether an error has occurred calculating this value
State Current Status of value
Substitution According to Project File Configuration
Scale Scaled values are defined in the configurator
Raw Value Scaling: The start of a raw value scaling is assigned to the scale start value and
changes after sensor calibration
Deviation Offset changes after sensor calibration
Gain Filter amplification factor
Lag Filter delay
Error Base Base error class and priority of the sensor when an error occurs