Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 81/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
2A10
Module Error
Internal module error (Null)
Turn the Ignition off and on again.
Consult Customer Service if the error
occurs again
2A11
Module Error
Internal module error (Zero ref.)
Turn the Ignition off and on again.
Consult Customer Service if the error
occurs again
2A12
Module Error
Internal module error (Ref. type)
Turn the Ignition off and on again.
Consult Customer Service if the error
occurs again
2EE5
Module Error
Unrecoverable RAM or FLASH memory
failure - the system is unsafe
Turn the Ignition off and on again.
Consult Customer Service if the error
occurs again
3001
Module Error
Data read/write failure
Turn the Ignition off and on again.
Consult Customer Service if the error
occurs again
3002
Module Error
Operating mode selection error - mode
is ignored
Turn the Ignition off and on again.
Consult Customer Service if the error
occurs again
3003
Module Error
Operating mode selection error
Select a valid Operating Mode
3004
Module Error
No valid Rated Load found
Select a valid Operating Mode and
operate within a valid Working Range
(load chart)
3005
Module Error
Operating mode selection error - mode
is void
Turn the Ignition off and on again.
Consult Customer Service if the error
occurs again
3006
Module Error
Unrecoverable RAM or FLASH memory
failure - the system is unsafe
Turn the Ignition off and on again.
Consult Customer Service if the error
occurs again
3007
Machine outside of Work-
ing Range
No load tables available because the
machine is outside the working limits
Return to the permitted Working
Range (load chart)
5001
Boom Length Calculation
Error
The Length Measurement is invalid
Check cable-reel mounting
Table 8 - 1