5-8
Drier
Nozzle
50 to 100 mm
b) Fill it up with the silicone sufficiently as shown below.
(B) Heat the filled part by a warm air of a drier (500W equivalent) for 7 to 8
minutes and cure the surface.
Caution: Keep the drier 50 to 100mm away so as not to deform the tube
by keeping it too close.
Silicone Filling Portion
(Hatching Portion)
The metallic portion of the
high-voltage line terminal portion
should be completely hidden.
Rib of the base plate
D section
Fill it up to approximately the same
height as the rib of the base plate so
that the screw head will not be out.
Rib
High-voltage round terminal
Fill up the downside of the terminal as well.