6-22 ● Transmission Sequences
● Bar code "used"→ "not used"
ESC Header 29H 30H
Use (0: not used; 1: used)
● Bar code "not used" → "used"
ESC Header 29H 31H ESC Header 2AH Type
Use (0: not used; 1: used)
Bar code type (0 to 6)
● EAN readable code (EAN-13)
ESC Header 7DH Code
Code type (0: None 1: 5x5 2: 5x7)
● Prefix code (EAN-13)
ESC Header 2CH Tens position Units position
Prefix code (00 to 99)
● Code set (Code128)
ESC Header 3FH Code set
0: code set B; 1: code set C
● Increased width
ESC Header 28H
Increased
width
Increased width (1to 9)
● Two or more print format items can be consecutively transmitted in a single chain.
(4) If you do not specify the item number, the setup data applies to all
print items.
NOTE: When transmitting print format and print specification data
consecutively in a single chain, ensure that the print format data
precedes the print specifications data.
If this order is reversed, a communication error occurs.
6.4.4-2 Text setup rules
(1) Print format
a) Line count
● When you change the line count for a print item in a certain column, you must also
set the line count for the other print items that belong to the same column.
(Example)
1357
2468
135
24678
Setting items 7
and 8 to one line
Transmit the line count consecutively to items 7 and 8. If you transmit the line count
to only one of them, a communication error occurs.
● When you change the line count for a print item, you must also set the line count for
the other print items that belong to the same column as the former one.
(Example)
135
24678
1357
2468
Setting items 7
and 8 to two lines
Transmit the line count consecutively to items 7 and 8. If you transmit the line
count to only one of them, a communication error occurs.