EasyManua.ls Logo

Hitachi RAS-3HVRNS - Page 314

Hitachi RAS-3HVRNS
482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Checking method of diode module
If items (a) to (d) are performing and the results are satisfactory,
the diode module is normal.
Measure it under 1kΩ range of a tester. Do NOT use a digital tester.
a. By touching the + side of the tester to the + terminal of diode
module and the - side of tester to the ~ terminals (3 NOs.) of the
diode module, measure the resistance.
If all the resistances are from 5 to 50kΩ, it is normal.
b. By touching the - side of the tester to the + terminal of diode
module and the + side of tester to the ~ terminals (3 NOs.) of the
diode module, measure the resistance.
If all the resistances are greater than 500kΩ, it is normal.
c. By touching the - side of the tester to the - terminal of diode
module and the + side of tester to the ~ terminals (3 NOs.) of the
diode module, measure the resistance.
If all the resistances are from 5 to 50kΩ, it is normal.
8 Troubleshooting
306
SMGB0060 rev. 1- 12/2010

Table of Contents