11.7 Reactor (DCL)
11.7.1 Reactor (DCL) for IVX Series
This part is used for changing the alternative current to the direct current for the inverter.
RAS-(4-6)HRNM1E (400V/50Hz), RAS-(8-12)HRNM (380-415V/50Hz)
Items Specifications
Character 1.0 mH+10% (at 1 kHz)
Rated current 30 A
Direct resistance
22.8 mΩ+20% (at 20 °C)
Permissible temperature range -20 ºC to 65 ºC
11.7.2 Reactor (DCL) for ES Series
This part is used for changing the alternative current to the direct current for the inverter.
RAS-(4-6)HVRNS1E (230V/50Hz)
Items
Specifications
Character 0.59 mH±15% (at 1 kHz)
Rated current 30 A
DC Resistance 26 mΩ (at 20 °C)
Permissible temperature range -20ºC to 60ºC
This part is used for changing the alternative current to the direct current for the inverter.
11 Electrical checks of
main parts
453
SMGB0060 rev. 1- 12/2010
11