EasyManua.ls Logo

Hitachi RAS-3HVRNS - Page 32

Hitachi RAS-3HVRNS
482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
¿ Suspended unit
1 Suspend the unit as shown in the figures.
2 Ensure that wall can withstand the weight of the outdoor unit indicated on the specifications plate.
3 It is advisable that each foot support should bear the full weight of the unit (in order take account of applied stress fatigue
when unit is operating).
RAS-3HVRNME
RAS-(4-6)H(V)RNM1E
RAS-(4-6)HVRNS1E RAS-(8-12)HRNM
RAS-(8/10)HRNSE
1
2
3
1
2
3
1. Wall support
2. Anchor bolts
3. Supplied by the installer
C A U T I O N
Follow these installation procedures carefully
The installation must be done so as to ensure that the outdoor unit does not lean, vibrate, make a noise or
fall in the event of strong gusts of wind or earthquakes. Calculate the resistance to vibration (caused by
earthquakes) to guarantee that the installation is sturdy enough to prevent falls. Secure the unit with cables
(field-supplied) when installing the unit in a place without walls or wind protection, and where it is likely to
be exposed to gusts of wind.
When using the vibration-proof rubber mat, secure it at four points on the front and back.
2 Unit Installation
24
SMGB0060 rev. 1- 12/2010

Table of Contents

Related product manuals