D A N G E R
• Check that the LED201 (red) located on the “W” surface PCB is OFF when opening the P-mounting plate.
• Do not touch the electrical components when LED201 (Red) located on the “W” surface PCB is ON in order to
avoid an electrical shock.
¿ Removing the coils for reversing and solenoid valve (SVA1, SVA2 and SVF)
1 Remove the service cover according to the section Removing service cover, see on page 366 in this chapter.
2 Open the P-mounting plate according to the section Opening electrical box (P-mounting plate), see on page 373 in this
chapter.
1. PCB.
2. Upper cover.
3. Rear cover.
1. Reversing valve coil.
2. SVA.
RAS-(4-6)HVRNM1E RAS-(4-6)HRNM1E
• 1. PCN7 (SVA) Solenoid valve.
• 2. PCN6 (RVR) Reversing valve coil.
• 1. PCN7 (SVA) Solenoid valve.
• 2. PCN6 (RVR) Reversing valve coil.
N O T E
• Do not touch the electrical components when the LED201 (Red), located on surface "W" PCB is ON in order to
avoid electrical shock.
• Remove the connectors on the control PCB of the electrical box.
• Remove the reversing valve coil by removing the screw fixing the coil.
10 Servicing
374
SMGB0060 rev. 1- 12/2010