EasyManuals Logo

Honeywell 1026FF02F9 User Manual

Honeywell 1026FF02F9
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Chapter 2 — Configure the Reader
24 IF1 Fixed RFID Reader Series User Manual
Configure the BRI Server Settings
Configure the BRI Server to handle communications between you
application and the RFID module.
1 Log in to the web browser interface and click RFID Services > BRI >
BRI Server.
2 Configure the BRI Server settings.
3 Click Activate Changes to save your changes.
BRI Server Settings
BRI Server settings handle communications between your application
and the RFID module.
BRI Server Settings
Setting Description
Enable External BRI
Connections
Enables external TCP connections to the BRI server. If this is not
enabled, BRI applications will not be able to connect to the reader.
BRI TCP Port Specifies the TCP port used for incoming connections to the BRI
server. This port must be unique for all TCP services running on
the reader. Valid range is 2189 to 65535. Default is 2189.
Enable Logging Enables logging of BRI server events.
Enable BRI on serial
port
Enables sending BRI commands through the serial port.
Serial Baud Rate Specifies the serial baud rate the reader uses to communicate.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 1026FF02F9 and is the answer not in the manual?

Honeywell 1026FF02F9 Specifications

General IconGeneral
BrandHoneywell
Model1026FF02F9
CategoryCard Reader
LanguageEnglish

Related product manuals