Alarms and events
This section describes how to determine your alarm and event requirements.
Issue Comments
Designing
alarm
systems
Consider and plan your alarm strategy.
Dynamic
Alarm
Suppression
Decide whether you want to enable Dynamic Alarm Suppression to deal with high
alarm situations like unit trips by temporarily but automatically removing certain
'flow-on' alarms from normal alarm views.
Alarm and
alert
shelving
Decide whether you want to enable alarm shelving. Enabling alarm shelving
allows operators to temporarily remove alarms from normal alarm views. For
example, if some equipment is out of action for maintenance, operators can
temporarily remove alarms associated with this equipment from their current alarm
view.
Alerts can also be shelved in the same way.
Alarm
prioritization
Formulate a set of rules and guidelines for prioritizing alarms.
System
alarm help
System alarm help is supplied with each release of Experion and can be tailored
for a customer's site. For more information about how to do this, see "Configuring
system alarm priorities and help" in the Station Configuration Guide.
Alarm
annunciation
Consider your alarm annunciation needs, such as buzzers and horns.
Alarm
groups
Decide whether you want to create alarm groups. Alarm groups provide an
alternative way of viewing alarms, which is not related to your asset model. For
example, you could create an alarm group to monitor alarms on all electrical
motors in your plant, regardless of their locations within the asset model.
System
alarm
groups
Decide whether you want to create system alarm groups. Unless stated otherwise,
the configuration and usage of system alarm groups is the same as alarm groups.
However, system alarm groups can only include system points and other system
alarm groups. They can be used to create a hierarchy of dashboards for the System
Status display. For more information, see Creating a dashboard hierarchy for the
System Status display” in the HMIWeb Display Building Guide.
Alarm
Tracker
Decide whether you want to create alarm trackers. An alarm tracker provides an
asset-based, graphical view of alarms over time that helps operators identify and
respond to abnormal situations like alarm floods. Alarm Tracker is an Experion
license option.
Alerts
Consider using alerts for notifications whose urgency and priority are not high
Alarms and events
Honeywell 2017 82

Table of Contents

Other manuals for Honeywell Experion LX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Experion LX and is the answer not in the manual?

Honeywell Experion LX Specifications

General IconGeneral
BrandHoneywell
ModelExperion LX
CategoryControl Systems
LanguageEnglish

Related product manuals