70 MPA2C3 Installation Guide
First on OSDP1 (Readers for Door 1 and 3). If the panel is a 2-door panel, then
the steps 1 to 4 are discarded.
1. Connect Door 3, Reader OUT from MPA2C1 on MPA2C3 OSDP1 terminal and
let it come online, it will show up in the Web interface as Door 3, Reader IN
2. Edit reader address and assign Door 3, Reader OUT
3. Connect Door 3, Reader IN from MPA2C1 on MPA2C3 OSDP1
4. terminal and let it come online, it will show up as Door 1, Reader OUT
5. Edit reader address and assign Door 3, Reader IN
6. Connect Door 1, Reader OUT from MPA2C1 on MPA2C3 OSDP1
7. terminal and let it come online, it will show up as Door 1, Reader IN
8. Edit reader address and assign Door 1, Reader OUT
9. Connect Door 1, Reader IN from MPA2C1 on MPA2C3 OSDP1
10. terminal and let it come online, it will show up as “New Reader with address 0”’
11. Assign reader address as Door 1, Reader IN
Next on OSDP2 (Readers for Door 2 and 4). If the panel is a 2-door panel, then
the steps 9 to 12 are discarded.
1. Connect Door 4, Reader OUT from MPA2C1 on MPA2C3 OSDP2 terminal and
let it come online, it will show up in the Web interface as Door 4, Reader IN
2. Edit reader address and assign Door 4, Reader OUT
3. Connect Door 4, Reader IN from MPA2C1 on MPA2C3 OSDP2
4. terminal and let it come online, it will show up as Door 2, Reader OUT
5. Edit reader address and assign Door 4, Reader IN
6. Connect Door 2, Reader OUT from MPA2C1 on MPA2C3 OSDP2
7. terminal and let it come online, it will show up as Door 2, Reader IN
8. Edit reader address and assign Door 2, Reader OUT
9. Connect Door 2, Reader IN from MPA2C1 on MPA2C3 OSDP2
10. terminal and let it come online, it will show up as “New Reader with address 0”
11. Assign reader address as Door 2, Reader IN
Option 2: reset all reader and reassign all one by one