Fabrics connected through FCIP merge if the ports are configured as VE_Ports, and do not
merge if one end of the connection is configured as a VEx_Port. If VE_Ports are used in a Fibre
Channel Routing Services backbone fabric configuration, then the backbone fabric merges
but the EX_Ports attached to edge fabrics do not merge. For more information, see the Fabric
OS Administrators Guide.
FCIP Trunking with load balancing and network-based failure recovery
Adaptive Rate Limiting
Configurable minimum and maximum committed bandwidth per FCIP tunnel
Minimum rate is guaranteed rate
FC Frame Compression before FCIP Encapsulation
FCR
SOTCP with reorder resistance
FastWrite over FCIP (not over FC)
Open Systems Tape Pipelining over FCIP
FCIP QoS
TCP Performance Graphing in Web Tools
FICON and FICON Cascading ready.
FICON CUP (requires an optional license).
FICON Accelerator for IBM TotalStorage z/OS Global Mirror (aka, XRC) and FICON Tape (requires
an optional license).
The 1606 Extension SAN Switch has the following hardware features:
Up to 16 Fibre Channel SFP ports supporting Fibre Channel Switching or Fibre Channel Routing
Services, with link speeds of 1-, 2-, 4-, or 8-Gb/s
Up to 6 1-GbE ports supporting the FCIP and Fibre Channel Routing Services features, with
transmit link speeds of up to 1-Gb/s on each port
Two ports (ge0 and ge1) can be configured for use with either copper or optical cables
Rackmountable 1U chassis
Two PowerPC 440EPx processors running at 667 MHz
One GoldenEye2 switch ASIC for 1, 2, 4, or 8 Gb/s FC switching
One Cavium CN5740 running with 8 MIPS cores at 750 MHz for data path processing
One Blaster FPGA for FC compression, offloads such as chksum generation/checks
One 10/100/1000 Base-T Ethernet port for the management interface
One RJ-45 terminal port
One USB port for storing firmware updates, supportSave command output, and configuration
uploads and downloads
Two redundant, hot-swappable combined power supply/fan assembly FRUs
Five internal temperature sensors