EasyManuals Logo

HP 3500 Series Advanced Traffic Management Guide

HP 3500 Series
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
2-16
GVRP
Configuring GVRP On a Switch
The show vlans command lists the dynamic (and static) VLANs in switch “B”
after it has learned and joined VLAN-222 and VLAN-333.
Figure 2-9. Example of Listing Showing Dynamic VLANs
Converting a Dynamic VLAN to a Static VLAN. If a port on the switch
has joined a dynamic VLAN, you can use the following command to convert
that dynamic VLAN to a static VLAN:
For example, to convert dynamic VLAN 333 (from the previous example) to a
static VLAN:
HP Switch(config)# static-vlan 333
When you convert a dynamic VLAN to a static VLAN, all ports on the switch
are assigned to the VLAN in Auto mode.
Switch “A”
GVRP enabled.
3 Static VLANs:
DEFAULT_VLAN
VLAN-222
VLAN-333
Switch “B”
GVRP enabled.
1 Static VLANs:
DEFAULT_VLAN
Port 1: Set to
“Learn” Mode
Dynamic VLANs
Learned from
Switch “A”
through Port 1
HP Switch(config)# show vlans
Status and Counters - VLAN Information
Maximum VLANs to support : 256
Primary VLAN : DEFAULT_VLAN
Management VLAN :
VLAN ID Name | Status Voice Jumbo
------- -------------------------- + ---------- ----- -----
1 DEFAULT_VLAN | Static No No
222 GVRP_222 | Dynamic No No
333 GVRP_333 | Dynamic No No
Syntax:
static-vlan < dynamic-vlan-id >
Converts the a dynamic VLAN to a static VLAN.

Table of Contents

Other manuals for HP 3500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3500 Series and is the answer not in the manual?

HP 3500 Series Specifications

General IconGeneral
ModelHP 3500 Series
LayerLayer 3
MAC Address Table Size16, 000 entries
TypeManaged
UplinkSFP
PoEOptional
ManagementWeb, CLI, SNMP
Routing ProtocolStatic, RIP
Power SupplyInternal
Form Factor1U rack-mountable
Jumbo Frame SupportYes
Operating Temperature32°F to 113°F (0°C to 45°C)
Ports24 or 48 10/100/1000 ports